35 resultados

  • SMARTair® ANSI

    Function

    Manages access to multiple doors with easy-to-use portable programmer and encoded, contactless electronic cards. 

    Applications

    Access control for commercial and institutional facilities, including offices, hospitals, factories, assisted living facilities, schools, sports clubs and more.


    Management options*

    Standalone; Offline; Update-On-Card (UOC); Wireless
    * Products are upgradable from Standalone to Wireless


    Features

    Wire-free installation
    Simple operation
    System management through easy-to-use software including: Authorizations; Time schedules; Daylight savings time and holidays; Deletion and replacement of lost tags; Audit trail (including registration of the internal handle); Escape - return feature; Door status indication: Door open, Door closed; 4 operation modes - Standard, Open, First person in, Dual user (available only in the wireless version)

    Scales up to 64,000 user cards and up to 64,000 doors per system



    Specifications

    13.56 MHz, HID iClass® DESFire & MIFARE® RFID technology
    Contactless RFID cards / tags / fobs / silicon & disposable wristbands
    2 possible memory configurations: 1,500 users and 600 events in the event log; 1,000 users and 1,000 events in the event log
    2 to 4 cm read/write distance
    Powered by 3 x AA batteries
    Conforms to ANSI grade 1
    ANSI A115 prep modified for through-bolts
    ADA-compliant levers
    RF module frequency: 915 MHz
    Shabbat compliant
    UL-3hour fire rate latch bolt
    Door width: 1 3/8" (35mm); 1 ¾" (44.5mm); 2 ¼" (57mm)


    Options

    Handles: SENA, TOLEDO
    Finish: Inox, Satin chrome, PVD polished brass, PVD satin brass
    Privacy feature
    May be installed with or without cylinder
    Cylinder options: Classic, Interactive®+, MT5®, 7x7, Integrator® platforms; Keyed different, Keyed alike; Master keying; '3 in 1' (changeable combination); FleX Control
    Internal / external models available
    Cylindrical version: 2¾" (70mm) backset - standard; 2⅜" (60mm) backset - available
    Mortise version: Automatic deadbolt - standard; Latch only version - available
    Installation with a Panic Exit Device (PED)

  • SMARTair® Knob Cylinder

    Function

    The SMARTair Knob Cylinder is an easy-to-use, simple-to-install, and highly effective electronic cylinder that can be integrated with other SMARTair locking elements − escutcheons, wall readers, e-motion − in one Access Control system managed by SMARTair Software.

    The Knob Cylinder is upgradable from Standalone to Offline/Update-On-Card and/or Wireless, making it the perfect solution for both new and retrofit installations.

    Mechanical features

    Freewheeling knob until an authorized credential is presented
    Motorized clutch activates cylinder cam
    Compatible with a mass variety of standard mortise locks (Euro, Scandinavian, Finnish and ANSI models are available)
    Panic function: Internal knob turning always opens door (only Euro model)
    Available Knob Cylinder models:
    Euro - Double cylinder (one or two electronic sides), half cylinder,

    Mortise cylinder 

    Scandinavian - Double cylinder (one or two electronic sides), half cylinder

    Reader module:

    13.56 MHz, MIFARE® DESFire or iClass technology
    Contact-less cards/tags
    Opening distance: 10mm with standard cards
    Programming device connection located on the front section of the electronic knob
    Indication light: Red & green LED

    Control Unit:

    Non-volatile memory
    Programmable in 3 modes: Normal mode - 1,500 users and 600 audit trail entries, Extended mode - 1,000 users and 1,000 audit trail entries, High traffic - All users of the installation have access and 1,000 audit trail entries, Real-time clock and calendar - 14 time profiles

    RF module (Wireless):

    868 MHz bi-directional radiofrequency technology
    Serves to send updates from the hub to the control unit, and to send audit trail from the control unit to the hub
    Encrypted communication
    Distance between the RF module and the hub: 25m

    Battery module:

    1 x CR123A Lithium battery
    Estimated battery life: 40,000 cycles; 2 years in standby (for the wireless model: 1-2 years in standby)
    Simple battery change; no dismounting required

    Specifications

    85% humidity without condensation
    Temperature range: 0°C to 70°C
    IP55 (extreme model)

  • SMARTair® Escutcheon (Standalone)

    The SMARTair wireless and battery powered escutcheons are ideal for transit, office or meeting room doors. The wide range of escutcheons offer a RFID reader amd locking mechanism in one for all kind of doors.

    Technical Data

    Door profiles - Suitable for wooden, narrow or glass doors
    Traffic volume - meduim to high
    Exterior usage - IP54 (Xetreme version) Up to 85% humidity -20 °C to +70 °C
    Hardware compatibility and installation - High retrofit (compatible with most common mortise locks). Drilling, no cabling. Doors from 30mm up to 110mm (thicker doors may be possible on demand)
    Power supply - Battery (from 60.000 to 80.000 cycles)* max. 2 years standby**
    Types of batteries:: 3 LR03 AAA 1.5V alkaline batteries
    Certification - CE (EMC, R&TTE). ROHS, REACH, WEE. EN1634 (Fire)
    RFID tegnologies - HID iClass(R). MIFARE Classic and Ultralight DESFire.
    System management upgradability - Escutcheons can be upgraded from standalone > Offline. Update on Card > Wireless online by:

    • Offline/UoC: firmware upgrade
    • Wireless Online:

    - Adding RF Module
    - Fireware upgrade
    - Change of internal cover (plastic top)


    * Depending on reading technology (MIFARE), iClass etc.)
    ** Depending on cycles per day.


    Electronic Technical Caracteristics

    Reader Module

    • Activation Mode: The escutcheon is activated without any previous contact with the escutcheon, just approching the credential, ensuring an efficient power consumption.
    • Reading distance: 2-4 cm read/write distance with standard RFID credentials.
    • Emergency openingL Jack connection is available to connect the emergency kit and to open with emergency or user card..
    • RFID reader with capacitive keypad and backlighting LEDs (green/red/blue) for different warning signals: access authorized or denied, low battery level, etc.
    • Buzzer included for PIN confirmation and access denied.

    Control Unit

    • Upgradeable firmware.
    • None-volatile memory.
    • 100 PINS per device. (4-6 digits)
    • 500 User cards per device.
    • Operating Modes:

     -- Standard: Default operating mode. Freewheeling handle until valid credential presented, then allows to open the door for 4-10 seconds.
    -- Passage mode: Escutcheon is always in open mode (cofigured by zones or by authorized user after double badging or double PIN).


    Battery Module

    • Easy battery change.
    • All Users (Cards and PINs) sign low batteries during the reading (red and green led blink). For very low batteries red and green led will blink alternatively but the escutcheon will not grant the access.  
  • SMARTair® Portable Programmer

    unction
    The SMARTair Portable Programmer serves as an interface between the SMARTair software and the SMARTair escutcheons, wall readers, cabinet locks (e-motion) and knob cylinders.

    The Portable Programmer enables the following:
    Initiate/update SMARTair escutcheons, wall readers, cabinet locks and knob cylinders
    Emergency opening of a door
    Testing of SMARTair escutcheons, wall readers and knob cylinders
    Retrieval of event logs from SMARTair escutcheons, wall readers and knob cylinders

    Specifications
    Membrane keyboard
    Power supply: 9V 6LR61 alkaline battery or 9V power supply adaptor; Auto switch-off after 30 seconds; Low-battery indication
    Connection to the PC − supplied with the portable programmer: Female RS-232 connector (serial port)
    Includes a dedicated cable to connect with the escutcheons and wall readers
    0.5 MB memory

  • SMARTair® Standalone Management Tools

    Function

    SMARTair Standalone is the basic version of SMARTair and manages access to a single door.
    Requiring no software or programming device, it relies on a friendly programming card to authorize or cancel electronic access cards.

    The Standalone Management Tools include
    Programming Card - used to program the SMARTair escutcheon, wall reader or knob cylinder
    Emergency cable - used to allow the opening of a door when the batteries are empty

    Programming Card features
    Add credential
    Cancel credential
    Cancel all credentials
    Passage mode control
    Shadow Card (to delete a lost credential)

    Programming Card options
    With Shadow Card feature
    Without Shadow Card features

    Emergency Cable features
    Used to energize the lock in order to open the door when the escutcheon's batteries are empty
    Requires 3 x AAA batteries

  • SMARTair® Updater

    Function

    The SMARTair Updater creates a virtual online network system without the drawbacks of a cable network but including all of its benefits.
    Updates are sent from the SMARTair software to the Updater (online) and are downloaded to the credential when it's presented to the Updater's wall reader.
    In turn, the credential then updates the escutcheons, wall readers, e-motion and knob cylinders of the system when presented. 
    The SMARTair Updater allows users to:
    Update credential authorizations without the need to go to the door with the portable programmer

    • Register new credentials (users) without the need to go to the door with the portable programmer
    • Collect audit trail from credentials
    • Manage battery status via the audit trail collected from credentials
    • Control doors - the Updater's wall readers can open doors and activate in/out locking 

    Features of the Updater  

    No limitation on the number of users per door
    Registers and deletes users in real time
    Enables recording and viewing of audit trails in the centralized database
    Provides Offline operation in the event of a communication failure (with no user quantity limit)
    The updater returns to online mode as it detects that communication has been re-established.
    Possibility of connecting a second wall reader to control not only the entrance, but also the exit
    Door indications

    Reader module

    With or without keypad
    -RFID only
    -RFID and code
    -Code only
    4-digit code
    Read/write contactless chip identification technology RFID 13.56 MHz ISO1443A MIFARE classic 1K and 4K and Ultralight or iClass
    Reading distance:10 mm with standard credentials
    Red and green indication light

    Control unit

    Non-volatile memory
    Operating mode:
    Standard: Default operating mode; authorized credential is required to open
    First user: The lock goes into passage mode after first access of an authorized credential

    Connections

    Power cable
    Ethernet TCP/IP
    PS/2 connector
    VGA connector for a screen (optional)
    Relay (for the wall readers)

    Specifications

    Power:
    Input:100-240VAC, 50/60Hz, 1A
    Output:7.5V, 1.2A
    Humidity: up to 85% without condensation
    Temperature range: from -10°C to 80°C
    IP54

    Updater case dimensions

    300mm x 300mm x 85mm

  • SMARTair® Software & License

    Function

    SMARTair Software (also called TS1000) enables users to manage the SMARTair system according to the license issued and the associated Authorization Key. 

    The SMARTair Software license includes:

    A USB memory device that contains: SMARTair Software installation file; Site data (the license); Technical manuals
    Authorization key programmed with the system's code
    The easy-to-use SMARTair Software manages all types of SMARTair products − escutcheons, wall readers, cabinet lock, knob cylinders and others − simultaneously.


    Software requirements

    PC with Pentium 4 processor or higher
    1 GB of free RAM
    1 GB or free disk space
    32-bit or 64-bit Microsoft Windows Operating System supporting services (Windows 95, Windows 98 and Windows ME are not supported)

    Site data

    The 'site data' is supplied with the software and includes the license for the system and a unique 8-figure alphanumeric system code
    All information regarding the system (user list, door list, authorization matrix, time profiles, etc.) is kept in the site data file

    Authorization Key

    The Authorization Key enhances security for the SMARTair system
    Each Authorization Key contains the system's unique corresponding
    system code
    In order for the Portable Programmer to function, the Authorization Key must be inserted. Without it, the Portable Programmer will not update the door or retrieve audit trails. It is possible to override the Portable Programmer by logging into the system's software

    Types of licenses

    For the different products (upgrades available): Offline; Update-On-Card (UOC); Genesis; Wireless
    According to the number of doors in the system (upgrade available): Up to 10 doors; Up to 30 doors; Up to 75 doors; More then 75 doors
    With Anti-Pass Back functionality (this feature is available with any license)

  • SMARTair® Relay Card

    Function

    The SMARTair Relay Card is a wall reader with an electronic card that includes 8 relays.
    The Relay Card can be a part of an Offline or Update-On-Card (UOC) system.

    Applications
    This device allows users to manage multiple relays to control systems like elevator floor access, gates and others.

    Features
    Simple operation
    System management through easy-to-use software including: Authorizations; Time schedules; Daylight savings time and holidays; Deletion and replacement of lost tags; Audit trails; Temporary blockage; 8 relays per controller; Possible to connect 5 controllers (up to 40 relays)

    Specifications
    13.56 MHz, MIFARE® technology
    Contactless cards
    2-4 cm read/write distance
    Temperature range: -10°C to 80°C
    12/24V AC/DC power
    8 Relays per card: NO, NC, C

  • SMARTair® Escutcheon (Offline, UOC, Wireless)

    The SMARTair wireless and battery powered escutcheons are ideal for transit, office or meeting room doors. The wide range of escutcheons offer a RFID reader amd locking mechanism in one for all kind of doors.

    Technical Data

    Door profiles - Suitable for wooden, narrow or glass doors
    Traffic volume - meduim to high
    Exterior usage - IP54 (Xetreme version) Up to 85% humidity -20 °C to +70 °C
    Hardware compatibility and installation - High retrofit (compatible with most common mortise locks). Drilling, no cabling. Doors from 30mm up to 110mm (thicker doors may be possible on demand)
    Power supply - Battery (from 60.000 to 80.000 cycles)* max. 2 years standby**
    Types of batteries:: 3 LR03 AAA 1.5V alkaline batteries
    Multi-authentication - RFID and PIN
    Status informatin - Handle usage. Thumb turn usage: only in privacy model/ door position: door sensor ot included. No (normally open) connection. Override cylinder (in combination with special mortise lock)
    Certification - CE (EMC, R&TTE). ROHS, REACH, WEE. EN1634 (Fire)
    RFID tegnologies - HID iClass(R). MIFARE Classic and Ultralight SKIDATA. DESFire.
    System management upgradability - Escutcheons can be upgraded from standalone > Offline. Update on Card > Wireless online by:
    - Adding RF Module
    - Fireware upgrade
    - Change of internal cover (plastic top)


    * Depending on reading technology (MIFARE), iClass etc.)
    ** Depending on cycles per day.


    Electronic Technical Caracteristics

    Reader Module

    • Activation Mode: The escutcheon is activated without any previous contact with the escutcheon, just approching the credential, ensuring an efficient power consumption.
    • Reading distance: 2-4 cm read/write distance with standard RFID credentials.
    • Emergency openingL Jack connection is available to connect the portable programmer and emergency kit.
    • RFID reader with capacitive keypad and backlighting LEDs (green/red/blue) for different warning signals: access authorized or denied, low battery level, etc.
    • Buzzer included for PIN confirmation and access denied.
    • Operating modes:

    -- Only RFID.
    -- Only PIN.
    -- RFID + PIN.
    -- PIN + RFID.


    Control Unit

    • Upgradeable firmware.
    • None-volatile memory. The escutcheon can be programmed to operate in 2 modes:

    -- Normal mode: 1500 users and 600 events.
    -- High traffic door: unlimited number of users filtered into 48 groups (permissions). Stores 1000 events.

    • Number of PINs:

    -- PIN + RFID (or RFID + PIN): unlimited PINs (stored in card).
    -- Only PIN mode: 8.
    -- 1 door PIN.
    -- 7 common PINs per installation selectable in each door.
    -- Type of PIN: 4-6 digits.

    • Real-time clock and calendar:

    -- 14 time zones with 5 time periods (week days and holidays selectable).
    -- State tables: configure 20 changes of operating modes in a door per day (switch door from lock to unlock).
    -- Yearly calendar: is updated every month automatically by the wireless system.
    -- Automatic DST: Daylight Saving Time change. Udatedwith calendar.

    • Operating modes:

    -- Standard: Default operating mode. Freewheeling handle until valid credential presented, then allows to open the door for 4-10 seconds (configurable).
    -- Standard ADA: Standard with double opening time.
    -- Passage mode: Escutcheon is always in open mode (cofigured by zones or by authorized user after doubke badging).
    -- Dpuble user: Two valid credentials needed to open the door.
    -- First User: lock in standard mode until first valid user enters, then will remain in passage mode (until closed by authorized user or automatically by time zone, state tables).

    Battery Module

    • Easy battery change.
    • Maintains clock/calendar for 5 minutes without batteries. 
    • Battery status reported on every event or once a day if no event happens. 

    RF Module

    • 868MHz or 915MHz selectable in field
    • 30 configurable channels: 

    -- From 868,00 to 875,25 in steps of 0,25Mhz each channel.
    -- From 915,00 to 922,25 in steps of 0,25Mhz each channel.

    • Auto-link with communication Habs (easy setup). 
    • Upgradable firmware. 
  • SMARTair® Narrow Wall Reader

    Function

    The SMARTair Wall Reader is a unique and elegant access control solution designed for simple installation and operation.
    The Wall Reader operates magnet locks, electric strike or electronic locks.
    All the control elements are on the inside of the door to enhance security.

    Applications
    Access control for commercial and institutional facilities, including offices, hospitals, factories, assisted living facilities, schools, sports clubs and more.

    Management options*
    Standalone; Offline; Update-On-Card (UOC)
    * Products are upgradable from Standalone to Offline/ Update-On-Card (UOC)

    Features
    Simple installation
    Simple operation
    System management through easy-to-use software including: Authorizations; Time schedules; Daylight savings time and holidays; Deletion and replacement of lost tags; Audit trail; Temporary blockage; 3 operation modes - Standard, Open, First person in
    Scales up to 64,000 user cards and up to 64,000 doors per system

    Specifications
    13.56 MHz, MIFARE® DESFire technology
    Contactless cards/tags
    2-4 cm read/write distance
    Temperature range: -10°C to 80°C
    12V AC/DC power
    Consumption: Relay not active - 20µA; Relay active - 150mA
    Relay: NO, NC, C

  • SMARTair® Encoder

    Function

    The SMARTair Encoder is a device that encodes and reads user credentials using the SMARTair software.

    Credentials

    Read/write contactless chip identification technology RFID 13.56 MHz: MIFARE Classic 1K, 4K, and ULTRALIGHT, DESFire
    ; iClass 2k/2, 16k/2, 16k/16, 32k
    Credential type: Card; Tag; Silicon bracelet; Transponder sticker; SynerKey

    Specifications

    Power cable − supplied with the encoder: Input - 100-240V 50/60 Hz 1.0A; Output - 7.5V 1.2A
    USB connection to the PC − supplied with the encoder
    Red & green indications

  • SMARTair® Wireless HUB

    Function

    The SMARTair Wireless HUB is the link between SMARTair Software  (TS1000) and the RF module in the SMARTair Wireless escutcheons, wall readers and knob cylinders. 

    Applications
    The SMARTair Wireless HUB receives information about changes and updates from the SMARTair software and transmits it to the SMARTair Wireless escutcheons, wall readers and knob cylinders.
    Audit trail details are sent in the reverse direction, from the SMARTair escutcheons, wall reader and knob cylinders to the software.

    Features
    Up to 100 HUBs in one system
    Up to 30 escutcheons/wall readers can communicate with one hub

    Specifications
    RF Module frequency: 868 MHz or 915 MHz
    TCP/IP connection to the PC network. Default details: IP address - 192.168.1.10; Subnet mask - 255.255.255.0; Gateway - 192.168.1.0
    Operating temperature: from 0°C to 60°C
    Humidity: 10%-90%, no condensing
    Power: 12 VDC or 230/110 VAC